Abstract

UV-Vis spectrophotometry and multivariate calibration model, Principal Components Regression (PCR), were used for individual and simultaneous quantification of ternary mixtures of reactive dyes (Yellow Procion HE4R, Navy Blue Procion HER, and Blue Procion HEGN) in a sample of industrial effluent and effluents obtained in the laboratory. A Centroid-Simplex-type experimental design was used. The percentages of the dyes Yellow Procion HE4R, Navy Blue Procion HER, and Blue Procion HEGN not fixed to the fiber in the industrial dyeing process and laboratory scale were 47.40%, 10.99%, 24.72% and 4.20%, 46.06%, 32.04%, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.