Abstract

SummaryThis study is carried out to evaluate the response modification, overstrength, and deflection amplification factors for steel diagrid system. To quantify these factors, the rational procedure introduced in Federal Emergency Management Agency (FEMA) P695, which is based on low probability of structural collapse and encompasses nonlinear static and dynamic analyses, is used. To this end, a series of diagrid structures with various slopes of external braces are designed. Nonlinear static analyses are performed to obtain system overstrength and period‐based ductility. Incremental dynamic analyses are then performed to assess collapse margin ratio (CMR) of the archetypes. The effects of spectral shape of different ground motions are considered in CMR values to obtain an adjusted CMR (ACMR), for each archetype. The values of calculated ACMRs are compared with the acceptable values of FEMA P695 to assess reliability of presumed seismic performance factors of diagrid systems. The results show that values of calculated ACMRs for steel diagrid systems designed using the response modification factor equal to 4.50 are acceptable. It is also observed that as the slope of the peripheral diagonal elements increases, the overstrength and the collapse margin ratios decrease, and the ductility of system increases.