Abstract

One of the complications of free flap breast reconstruction is the occurrence of skin and fat necrosis. Intra-operative use of near-infrared (NIR) fluorescence imaging with Indocyanine Green (ICG) has the potential to predict these complications. In this study, the quantification of the fluorescence intensity measured in free flap breast reconstruction was performed to gain insight into the perfusion patterns observed with ICG NIR fluorescence imaging. ICG NIR fluorescence imaging was performed in patients undergoing free flap breast reconstruction following mastectomy. After completion of the arterial and venous anastomosis, 7.5mg ICG was administered intravenously. The fluorescence intensity over time was recorded using the Quest Spectrum Platform®. Four regions of interest (ROI) were selected based on location and interpretation of the NIR fluorescence signal: (1) The perforator, (2) normal perfusion, (3) questionable perfusion, and (4) low perfusion. Time-intensity curves were analyzed, and two parameters were extracted: Tmax and Tmax slopes. Successful ICG NIR fluorescence imaging was performed in 13 patients undergoing 17 free flap procedures. Region selection included 16 perforators, 17 normal perfusions, 8 questionable perfusions, and 5 low perfusion ROIs. Time-intensity curves of the perforator ROIs were comparable to the ROIs of normal perfusion and demonstrated a fast inflow. No outflow was observed for the ROIs with questionable and low perfusion. This study provides insight into the perfusion patterns observed with ICG NIR fluorescence imaging in free flap breast reconstruction. Future studies should correlate quantitative parameters with clinical perfusion assessment and outcome.

Highlights

  • Breast cancer accounts for 30 percent of newly diagnosed malignancies in female patients, and it is the leading cause of death among middle-aged women[1]

  • Possible techniques to aid the surgeon while assessing tissue perfusion include laser doppler and near-infrared (NIR) fluorescence imaging with Indocyanine Green (ICG)[7]

  • Successful ICG NIR fluorescence imaging was performed in 13 patients undergoing 13 deep inferior epigastric artery perforator (DIEP), 3 profunda artery perforator (PAP), and 1 superficial inferior epigastric artery (SIEA) flap reconstruction(s)

Read more

Summary

Introduction

Breast cancer accounts for 30 percent of newly diagnosed malignancies in female patients, and it is the leading cause of death among middle-aged women[1]. For patients undergoing breast (reconstructive) surgery, the intra-operative use of ICG NIR fluorescence imaging was demonstrated to aid surgeons in their assessment of skin viability, thereby reducing the occurrence of skin necrosis in several studies[10,11]. This reduction in necrosis can be explained by the intra-operative removal of tissue with diminished fluorescence intensity observed with ICG NIR fluorescence imaging. The aim of this study was to gain insight into these perfusion patterns by performing a quantitative assessment of the ICG NIR fluorescence imaging used in free flap breast reconstruction

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.