Abstract

In this project, we have attempted to develop a new technique utilizing Boron-doped diamond (BDD) films to electrochemically detect mercury dissolved in solution via the initial deposition of metallic mercury, followed by anodic linear sweep voltammetry in the range from 10-10{sup -10} M to 10{sup -5} M. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were employed. The extremely low background current for BDD electrodes compared to glassy carbon (GC) provides a strong advantage in trace metal detection. CV peak currents showed good linearity in the micromolar range. A detection level of 6.8 x 10{sup -10} M was achieved with DPV in 0.1 M KNO{sub 3} (pH = 1) for a deposition time of 20 minutes. Reproducible stripping peaks were obtained, even for the low concentration range. A comparison with GC shows that BDD is superior. Linear behavior was also obtained in the mercury concentration range from 10{sup -10} M to 10{sup -9} M.