Abstract

To quantify small amounts of iron-labeled cells in mouse brains with magnetic resonance imaging (MRI). Iron-labeled cells (from 500 to 7,500) were stereotaxically transplanted into the brain of living mice that were subsequently imaged with MRI at 4.7 T. We compared four quantitative methods: (1) T2 relaxometry, (2) T2* relaxometry, (3) the volume of the cloverleaf hypointense artifact generated on T2*-weighted images, and (4) the volume of the cloverleaf hyperintense artifact generated on positive contrast images. The methods based on relaxometry, whether T2 or T2*, did not correlate with the number of injected cells. By contrast, those based on measurement of cloverleaf artifact volume, whether using negative or positive enhancement, showed a significant linear relationship for the given range of cells (R [0.92-0.95], p < 0.05). T2* artifact volume imaging (negative or positive) appears promising for the quantification of magnetically labeled cells following focal injection in the brain.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.