Abstract

A new method for the determination of caffeine, a non-fluorescent analyte, based on the enhancement of the fluorescence of Rhodamine B dye on a membrane filter modified with multi-walled carbon nanotubes is proposed. The method comprises pre-concentration of caffeine on a solid support by chemofiltration in buffered solution onto multi-walled carbon nanotubes previously oxidised and dispersed in cationic surfactant admicelles. The effect of experimental parameters, including the nature of the buffer and pH, the nature of the solid support, filtration flow rate, dye and carbon nanotube concentration, and the nature of the surfactant and concentration were investigated by means univariation assays. Under optimum experimental conditions, the pre-concentration system gave detection and quantification limits of 0.3 and 1.1 µg l−1, respectively. A wide linear range was achieved varying from concentrations of 1.1 to 9.7 × 103 µg l−1 (r2 = 0.999). Satisfactory recovery values were obtained using the method of standard addition, confirming the feasibility of this method for caffeine determination in energising dietary supplements and energy drinks.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.