Abstract

The quadriceps tendon (QT) has recently gained interest as an anterior cruciate ligament reconstruction (ACLR) autograft. There is a paucity of data from large cohort studies on failures and revision rates after ACLR using the QT graft. The purpose of the present study is to use the Danish Knee Ligament Reconstruction Registry (DKRR) to compare revision rates, objective knee stability and subjective clinical outcomes in patients who have undergone ACLR with QT, hamstring tendon (HT), and patellar tendon (PT) as a graft for ACLR. It was hypothesized that QT autografts would result in similar objective knee stability and revision rates as HT and PT autografts. Data on primary ACLRs in the DKRR from 2005 through 2017 were analyzed. Knee injury and Osteoarthritis Outcome Scores (KOOS), Tegner activity scale scores, sagittal knee laxity, pivot-shift tests at 1-year follow-up and revision rates at 2-year follow-up were compared for the three autograft cohorts. A total of 531 QT, 14,213 HT and 1835 PT ACLR were registered in the DKLR between 2005 and 2017. QT autograft was associated with statistically significant increased laxity (1.8 mm) compared to HT autograft (1.5 mm) (p < 0.001) and more positive pivot shift. There was a significant higher revision rate for QT (4.7%), compared to PT (1.5%) and HT (2.3%) autografts at 2-year follow-up (p < 0.002). Quadriceps tendon autografts for ACLR was associated with higher revision rates than HT and PT grafts. QT graft was also associated with small increased objective knee laxity and more positive pivot shift than HT and PT grafts. III.