Abstract

A pupil plane filtering technique is applied to data signal detection in an optical data storage system that uses a solid immersion lens (SIL) and a quadrilayer phase change recording medium. Two systems that have the effective numerical aperture (NAEFF) of 1.1 and 2.0 are investigated. A new filter is designed for the NAEFF=2.0 system on the basis of this study. We have confirmed by numerical calculations that the technique improves signal contrast, which is defined by the ratio of the difference signal to the sum signal between the homogeneous crystalline area and the homogeneous amorphous area. We have also confirmed that the technique makes the contrast less sensitive to the gap width between the SIL and the recording medium. The vectorial feature of the light is considered in the calculations. The calculated irradiance distributions and signal levels for the system with NAEFF =1.1 are confirmed by experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.