Abstract

Several laboratories have used the pulsed wire method for magnetic field measurement. The acoustic wave distortion of the wire was observed. The limitations of this method were discussed. A pulsed wire system is under test in SRRC on an undulator U10p with a total length of 2m. In this paper the authors clarify the effect of wire imperfection and dispersion of acoustic wave, which are deemed to the main sources of the distortion and limitations. A strategy using thick wire is proposed to make this method reliable in precise measurement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.