Abstract
Pulse stress tests on magnetic tunnel junctions (MTJs) with a MgO barrier (~5.5 Aring) were conducted. Both the E (McPherson and Mogul, 1998) and 1/E (Chen and Holland, 1985; Schuegraf and Hu, 1994) models can describe the intrinsic breakdown behavior of this ultrathin barrier within the range of voltages studied. While constant voltage stress (CVS) and ramped voltage pulse stress (RVPS) testing yield different experimental failure times for the same failure voltage, accounting for the buildup of degradation from each pulse in the RVPS testing yields the same fundamental degradation rate for the two techniques. The barrier parameter change (before hard breakdown) is related to trap generation and trapped electrons. The variation in the barrier parameters after constant stress testing was also studied by fitting I-V data using Simmons' model (1963). A decrease in the effective barrier thickness and an increase in the effective barrier height were found after constant current/voltage stress. Annealing MTJs with minor damage for 2 hours at 120degC restored the stressed barrier to its initial state.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.