Abstract
Plasma pulse generators are used widely in scientific investigations and in industrial technologies. The main spheres of plasma generators application are enumerated in this work. Simplified design of pulse plasma generator with coaxial electrode system is presented. Typical oscillograms of discharge current, voltage drop on the arc, pressure in discharge chamber and power chart of the arc are shown. The following parameters of plasma and current discharge pulses were obtained in the process of investigations: discharge current - up to 2 MA; energy input - up to 10 MJ; maximum discharge power - up to 2·10<sup>10</sup> V·A; time of discharge - (0.3-2.0)·10<sup>−3</sup> s; pulse pressure in the discharge chamber - up to 600 MPa; average mass temperature - from 2·10<sup>3</sup> up to 10<sup>5</sup> K. The new possible area of pulse plasma generators application the destruction of high toxic and industrial wastes is stated.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have