Abstract
Proton transfer reaction mass spectrometry (PTR-MS) based on reactions of H 3O + ions has been used to measure the concentrations of propanol in 46 healthy persons, yielding an average concentration of about 150 ppb. That the measurements were not obscured by other components of the same mass as propanol was proven by comparison of PTR-MS data with separate selected-ion flow-drift tube (SIFDT) investigations of the energy dependences of reactions of H 3O + and H 3O +·H 2O with isopropanol, n-propanol, acetic acid and methyl formate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Mass Spectrometry and Ion Processes
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.