Abstract

Most current proton FLASH-RT studies focus on transmission proton techniques. In this study, we propose a novel method for achieving FLASH dose rate in hypofractionated proton radiotherapy using the Bragg peak of a single-energy proton beam. The dosimetric characteristics using this novel technique for proton pencil beam scanning (PBS) stereotactic body radiation therapy (SBRT) of prostate and breast cancers were first investigated based on the clinically available cyclotron beam parameters. This novel approach uses the distal tracking technique that enables PBS Bragg-peak of the highest proton energy to adapt to the target distally. Positioning of the Bragg peak at different depths is achieved using a universal range shifter and range compensator. To investigate the feasibility of this approach, we developed an in-house treatment planning platform for intensity-modulated proton therapy (IMPT) delivery and performed dosimetric studies on prostate and breast SBRT cases previously treated with conventional proton PBS technique. FLASH plans were generated using a similar clinical beam arrangement to deliver 40 Gy (RBE) in 5 fractions. Dose metrics were compared between the clinical and FLASH plans. Dose-rate volume histograms (DRVH) were also calculated to investigate the 40 Gy/s coverage (V40 Gy/s) of organs-at-risk (OARs) for FLASH plans. The distal tracking can precisely stop the Bragg peak at the target distal edge, and Bragg peak plans achieved tumor coverage and dose conformality equivalent to IMPT plans. The clinical IMPT plans yielded slightly superior target dose uniformity -CTV Dmax of FLASH plans was 10% higher for prostate and 2% higher for breast. There was no significant difference between the clinical and FLASH plans in dose metrics for major OARs, including rectum, large bowel, heart, and lung. Higher maximal doses to femoral heads (∼2 Gy) and urethra (∼6 Gy) were observed in prostate FLASH plans than in the clinical plans but were still within clinically accepted dose limits. The V40 Gy/s for OARs were >90% for prostate FLASH plans and >76.5% for breast FLASH plans. The proposed single-energy Bragg-peak FLASH technique eliminates exit dose associated with transmission proton FLASH and can still yield comparable plan quality and OAR sparing while preserve sufficient FLASH dose rate coverage for prostate and breast proton SBRT. This study demonstrates the potential application of Bragg peaks for highly conformal FLASH-RT using clinical cyclotron systems to treat prostate and breast cancer patients, which moves towards clinical application.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call