Abstract

This paper evaluates the effects of severity of Torsional Irregularity (TI) and In-plane Discontinuity in Vertical Lateral force-resisting element Irregularity (IDVLI) together with seismic strength of the building on the progressive collapse potential of steel Special Moment-Resisting Frames (steel SMRFs), which were designed based on common seismic codes. In order to investigate the progressive collapse potential according to GSA 2013 guidelines, an interior or exterior column is removed in 3D modeled building using nonlinear dynamic analysis. Various TIs by defining the ratio of maximum relative lateral displacement of the story to average relative lateral displacement of the story between 1 to 1.6 and IDVLIs by disconnecting one or two columns in the first and second stories are selected. Buildings are 3, 6 and 9 stories high, and Los Angeles, California andGeorgia sites with high, moderate and low levels of seismicity, respectively, are considered. All corresponding buildings have similar seismic mass and are designed for approximately equal values of earthquake base shear, so the comparison process can be possible due to the comparison of equivalent-designed buildings. Gravity and seismic loads of buildings are applied based on ASCE 7-05, and steel design is carried out based on AISC 2010. The results show that buildings designed with greater TI have greater resistance to the progressive collapse phenomenon. Furthermore, buildings in a site with higher seismicity level have less progressive collapse potential. In IDVLI, the buildings located in a site with low seismicity are always rejected against progressive failure based on GSA 2013, whereas buildings located in a site with high seismicity are always acceptable. In addition, in a system with IDVLI, the scenario of external column removal always creates more critical conditions. Results toward the combined effects of irregularity and seismicity level of sites are presented.

Highlights

  • Attention to the issue of progressive collapse was made for the first time in the engineering community due to occurrence of a local collapse in the 22-story Ronan Point building [1] in London, which happened in 1968 due to gas leakage on the eighteenth story

  • The results showed that the irregular building located in the site with soil class C had the worst conditions, and in the case of the buildings located in a site with soil class E the demand to capacity ratio (D/C) of column in the irregular building was twice that of the regular building

  • There is a significant relation between seismic hazard level and the amount of formation of plastic hinges in progressive collapse analysis of the buildings

Read more

Summary

Introduction

Attention to the issue of progressive collapse was made for the first time in the engineering community due to occurrence of a local collapse in the 22-story Ronan Point building [1] in London, which happened in 1968 due to gas leakage on the eighteenth story. Murrah building [2] in Oklahoma in 1995 was one of the largest terrorist incidents that led to a progressive collapse phenomenon, causing a loss of 652 million dollars. The progressive failure in the Plasco building in Tehran [5, 6] caused by fire was another tragedy, resulting in the death of twenty firefighters (Fig. 1). Standards for the design and control of buildings against progressive failure include the guidelines of the US Department of Defense (DoD) [7] and the US

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call