Amendments to "Procedure for the Analysis and Design of Ductile Reinforced Concrete Frame Buildings of Moderate Height" - R. L. Williams, published Bulletin of the N.Z.N.S.E.E. Vol. 8, No. 4, December, 1975.

Highlights

  • Relaxed to, say 2/3rds of this value as under these conditions it is most unlikely that plastic hinges can form at top and bottom of the column simultaneously

  • Special Transverse Reinforcement is required through the joint plus a distance either side equal to the columns largest dimension or the column height ^ 6 if greater

  • DELETE: a 50% reduction within the column joint is allowable if the joint is confined on 4 faces

Read more

Summary

Introduction

Relaxed to, say 2/3rds of this value as under these conditions it is most unlikely that plastic hinges can form at top and bottom of the column simultaneously. Special Transverse Reinforcement is required through the joint plus a distance either side equal to the columns largest dimension or the column height ^ 6 if greater.