Abstract

The paper presents validation of known calculation dependencies used in RELAP-5 and other advanced computer codes to predict thermohydraulic anomalies from the standpoint of analyzing effect of initial coolant boiling in the Chornobyl accident on its further progression. The authors show current unsatisfactory efficiency of state-of-the-art computer codes in definition of the initial boiling point for the coolant in water-cooled nuclear reactors. The calculation methodology for improving accuracy in the predicting of dangerous thermal anomaly in reactor channels is under consideration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.