Abstract

in 600 MW unit of a certain power company, the frequency conversion transformation on an axial FGD booster fan had been done, but it was found that have only little energy-saving effect and the investment recovery period would be very long. Based on performance characteristics test, the reason of this problem was analyzed. It shows that the transformation scheme in effect is unsuitable. The optimized scheme was proposed and suggesting good effect through energy-saving estimate. The company implemented optimization and then found the energy-saving index is almost the same as estimate. This problem is representative for frequency conversion transformation of fans, it can be avoided through performance characteristics test and energy-saving estimate before transformation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.