Abstract
A detailed fuel rod design is carried out for the first time in the development of Supercritical-pressure Light Water Reactor (Super LWR). The fuel rod design is similar to that of LWR, consisting of UO 2 pellets, a gas plenum and a Stainless Steel Cladding. The principle of rationalizing the criteria for abnormal transients of the Super LWR is developed. The fuel rod integrities can be assured by preventing plastic strains on the cladding, preventing the cladding buckling collapse, and keeping the pellet centerline temperature below its melting point. The FEMAXI-6 fuel analysis code is used to evaluate the fuel rod integrities in abnormal transient conditions. Detailed analyses have shown that allowable limits to the maximum fuel rod power and maximum cladding temperature can be determined to assure the fuel integrities. These limits may be useful in the plant safety analyses to confirm the fuel integrities during abnormal transients.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.