Abstract

BackgroundInfection of implanted medical devices has catastrophic consequences. For cardiac rhythm devices, pre-procedural cefazolin is standard prophylaxis but does not protect against methicillin-resistant gram-positive organisms, which are common pathogens in device infections. ObjectiveThis study tested the clinical effectiveness of incremental perioperative antibiotics to reduce device infection. MethodsThe authors performed a cluster randomized crossover trial with 4 randomly assigned 6-month periods, during which centers used either conventional or incremental periprocedural antibiotics for all cardiac implantable electronic device procedures as standard procedure. Conventional treatment was pre-procedural cefazolin infusion. Incremental treatment was pre-procedural cefazolin plus vancomycin, intraprocedural bacitracin pocket wash, and 2-day post-procedural oral cephalexin. The primary outcome was 1-year hospitalization for device infection in the high-risk group, analyzed by hierarchical logistic regression modeling, adjusting for random cluster and cluster-period effects. ResultsDevice procedures were performed in 28 centers in 19,603 patients, of whom 12,842 were high risk. Infection occurred in 99 patients (1.03%) receiving conventional treatment, and in 78 (0.78%) receiving incremental treatment (odds ratio: 0.77; 95% confidence interval: 0.56 to 1.05; p = 0.10). In high-risk patients, hospitalization for infection occurred in 77 patients (1.23%) receiving conventional antibiotics and in 66 (1.01%) receiving incremental antibiotics (odds ratio: 0.82; 95% confidence interval: 0.59 to 1.15; p = 0.26). Subgroup analysis did not identify relevant patient or site characteristics with significant benefit from incremental therapy. ConclusionsThe cluster crossover design efficiently tested clinical effectiveness of incremental antibiotics to reduce device infection. Device infection rates were low. The observed difference in infection rates was not statistically significant. (Prevention of Arrhythmia Device Infection Trial [PADIT Pilot] [PADIT]; NCT01002911)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.