Abstract

The use of an antibacterial envelope is cost-effective for patients at high risk of developing cardiac implantable electronic device (CIED) infection. The identification of these high-risk patients may be facilitated using a clinical risk score. The aim of the current study is to evaluate the PADIT score for identifying high-risk patients in patients undergoing a CIED procedure in a tertiary academic center. This was a retrospective single-center study of consecutive patients undergoing a CIED procedure between January 2016 and November 2021. Patients who received an antibacterial envelope were excluded from this study. The primary endpoint was hospitalization for a CIED infection in the first year after the procedure. A total of 2333 CIED procedures were performed in the study period (mean age 61.6 ± 16.3years, male sex 64.5%, previous CIED infection 1.7%, immunocompromised 5.4%). The median PADIT score was 4 (interquartile range, 2-6). CIED infection occurred in 10 patients (0.43%). The PADIT score had good discrimination in predicting major CIED infection (C-statistic 0.70; 95% confidence interval [CI] 0.54 to 0.86, P = 0.03). Using an optimal PADIT score cut-off value of 7, the risk of CIED infection was higher in the patients with a PADIT score of ≥ 7 in comparison to those with a lower PADIT score (1.23% vs. 0.26%, P = 0.02; odds ratio 4.8, 95% CI 1.4 to 16.6, P = 0.01). The PADIT score is a clinically useful score for identifying patients at high risk of developing CIED infection. The use of an antibacterial envelope in these high-risk patients may be cost-effective.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call