Abstract
ABSTRACTAir release through venting devices during filling operations of an empty pipeline can give rise to vast transients which can result in serious damages to the pipes. However, despite a large number of studies, there is still a significant lack of knowledge regarding the physical processes involved. The present paper aims to address this issue by comprehensive laboratory tests. Two configurations were analysed and both air release valves and orifices were used for air venting. In the first configuration, the air vent was fitted at the downstream end of the pipeline, and the transient showed significant pressure surges consequent to the high velocity impact of the water column on the orifice (or the valve). In the second configuration, the air vent was fitted at an intermediate high point of the pipe profile. In this case, the transient showed very low velocity of the water column at the impact and, consequently, generally negligible pressure surges.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.