Abstract

Patients critically ill with COVID-19 are at risk for hospital-acquired pressure injury, including device-related pressure injury. Braden Scale predictive validity was compared between patients with and without COVID-19, and a logistic regression model was developed to identify risk factors for device-related pressure injury. A total of 1920 patients were included in the study sample, including 407 with COVID-19. Among the latter group, at least 1 hospital-acquired pressure injury developed in each of 120 patients (29%); of those, device-related pressure injury developed in 55 patients (46%). The Braden Scale score area under the receiver operating characteristic curve was 0.72 in patients without COVID-19 and 0.71 in patients with COVID-19, indicating fair to poor discrimination. Fragile skin and prone positioning during mechanical ventilatory support were risk factors for device-related pressure injury. Clinicians may consider incorporating factors not included in the Braden Scale (eg, oxygenation and perfusion) in routine risk assessment and should maintain vigilance in their efforts to protect patients with COVID-19 from device-related pressure injury.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call