Abstract

An experimental investigation has been carried out to find the pressure difference of the process of steam condensation across the port to channel in plate heat exchangers. In the present study, low corrugation angle (30°) plates have been used for different number of channels, namely, 10 and 80. The process steam entered at 1 bar with a small degree of superheat. Water has been used as the cold fluid. The pressure probes are inserted through the plate gasket into both the inlet and exit ports of the channel. The pressure drop of the process steam has been measured and recorded at the first, middle, and last channels at different flow and exit conditions for each plate package of the heat exchanger. Also, the overall pressure drop has been measured at different conditions at the outlet of the process steam, i.e., full and partial condensation. The pressure drop measurements have indicated that there is a considerable variation in pressure drop from the first channel to the last channel due to flow maldistribution. The experimental data has been analyzed to show how the flow maldistribution affects the pressure drop of a plate condenser.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.