Abstract

Pressure drop measurements in a 15-row steam condenser configured with in-line tubes, p/D < 1.33, are described. Pressures from 50 to 100 mb and Remax in the range 1,000-18,000 were imposed. It is shown that pressure loss coefficients for the bundle and for two-row pairs were lower than predictions for equivalent single-phase tests except near the bottom of the bundle. There was some evidence that increase in suction parameter increased this effect in the top rows. Taken together with previous investigations [3, 4], a falling trend of suction effect is evident the more closely packed the tubes are. The discrepancy between these findings and the results of simulation experiments [7] is noted.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.