Abstract

ABSTRACT Pin fin arrays, which have a high heat transfer capacity and minimal pressure loss, are currently being used as the primary cooling technique for the turbine trailing edge cooling channel used in modern gas turbines. To enhance the heat transmission efficiency of the channel, this study proposes the use of a circular-shaped pin and a teardrop pin, through both experimental and numerical investigations. The numerical simulations conducted in the Reynolds number range of 10,000 to 80,000 are used to investigate and compare the flow and heat transfer parameters of a wedge channel which has three rows of staggered circular-shaped and teardrop-shaped pin fins with a diameter of 12 mm. The experiment showed that teardrop pin fns with staggered arrangement has different effect on flow pattern and heat transfer characteristics. Heat transfer is increased by 10.45% when compared to the circular pin fins and the pressure drop of teardrop pin fins is reduced by 54.6%.Therefore thermal performance factor exhibits a 25.4% increase when compared to circular fins.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.