Abstract

In order to grasp the distribution characteristics of the pressure field on the inner wall of the volute casing of an atypical open impeller centrifugal pump, the instantaneous pressure at different operating conditions was experimentally measured under four operating rotational speeds to obtain the distribution characteristics of the average static pressure field in the volute casing of this pump model. The pressure pulsation amplitude and pressure pulsation intensity were also analyzed at different rotational speed cases, and the standard deviation analysis was performed. The results showed that the instantaneous pressure pulsation on the inner wall of the volute casing strongly fluctuates during the pump operating, and the closer to the volute casing outlet, the more intense the pressure pulsation was. After increasing the pump shaft speed, the fluctuation amplitude gradually decreased. The pressure pulsation on the wall of tip clearance is more intense than that on the inner wall of the volute shell. The intensity of the pressure pulsation on the wall of tip clearance decreases with the increase of the rotational speed, and the higher the speed, the less intense the pressure pulsation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call