The ferrite plating with applying power ultrasound waves of 19.5 kHz and 600 W enabled us to encapsulate entirely MnZn ferrite cores for transformers with Ni/sub x/Zn/sub y/Fe/sub 3-x-y/O/sub 4/ coating. Supplying a NH/sub 4/OH solution during the plating broke the limit of the solubility of Ni ions to ferrite-plated films. The electrical resistance of the NiZn ferrite increased with increasing the Ni and Zn content, reaching 2.3/spl times/10/sup 5/ /spl Omega/ cm at the composition of Ni/sub 0.24/Zn/sub 0.30/Fe/sub 2.46/O/sub 4/. The saturation magnetization was 540 emu/cm/sup 3/. The MnZn ferrite cores were successfully encapsulated with NiZn ferrite coating, resulting in the increase of their surface resistance to over 100 k/spl Omega/.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.