Abstract

The HCPB TBS (Helium-Cooled Pebble Bed Test Blanket System) is one of the two European TBSs that will be installed and tested in the ITER reactor. The use of flanged connections in the Helium Coolant System and the Tritium Extraction System of the HCPB TBS would make the remote maintenance operations easier and faster. Therefore, investigating the helium leakage from flanges becomes a fundamental step toward the control of the tritium activity in the Port Cell, as the helium flow will contain a variable but not negligible amount of tritium. The first set of experiments on helium leakages from flanged connections is described in this paper. The experiments were performed in a HeFUS3 facility, an eight-shaped helium loop designed to work at HCPB-TBS-relevant conditions. The facility can provide a helium mass flow rate in the range of 0.27–1.4 kg/s and can reach a pressure as high as 80 bar and a temperature up to 530 °C. Two types of gaskets were tested in this campaign: a spiral-wound gasket and an oval ring joint. The gasket/flange assemblies are described in detail in this paper, together with the test section that hosts them and the performed commissioning tests. The tests were carried out at 500 °C and 80 bar. In these conditions, the leak rate from the flange with the oval ring joint resulted in being, on average, 1.42·10−6 mbar∙L/s, while the leak rate from the flange with the spiral-wound gasket resulted in being, on average, 3.73·10−3 mbar∙L/s.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call