Abstract

BackgroundDespite increasing attention in the cardiac anesthesiology literature, continuous measurement of right ventricular pressure using a pulmonary artery catheter has not been described in orthotopic liver transplantation, despite similarities in the anesthetic approach to the two populations. We describe our preliminary experience with this technique in orthotopic liver transplantation, and by combining various derived measures with trans-esophageal echocardiography, make some early observations regarding the response of these measures of right ventricular function during the procedure.MethodsIn this case series, ten patients (five men and five women) undergoing orthotopic liver transplantation in our institution had their surgeries performed while monitored with a pulmonary artery catheter with continuous right ventricular port transduction and trans-esophageal echocardiography. We recorded various right ventricular waveform (early-to-end diastolic pressure difference, right ventricular outflow tract gradient, right ventricular dP/dT and right ventricular end-diastolic pressure) and echocardiographic (right ventricular fractional area change, tricuspid annular plane systolic excursion, right ventricular lateral wall strain) and described their change relative to baseline at timepoints five minutes before and after portal vein reperfusion, immediately after hepatic artery reperfusion and on abdominal closure.ResultsExcept for tricuspid annular plane systolic excursion at five minutes prior to reperfusion (mean −0.8 cm; 95% CI−1.4, –0.3; p = 0.007), no echocardiographic metric was statistically significantly different at any timepoint relative to baseline. In contrast, changes in right ventricular outflow tract gradient and right ventricular dP/dt were highly significant at multiple timepoints, generally peaking immediately before or after reperfusion before reducing, but not returning to baseline in the neohepatic phase. Nine of 10 participants in this series demonstrated a degree of dynamic right ventricular outflow tract obstruction, which met criteria for hemodynamic significance (> 25 mmHg) in two participants. These changes were not materially affected by cardiac index.ConclusionsDynamic right ventricular outflow tract obstruction of varying severity appears common in patients undergoing orthotopic liver transplantation. These results are hypothesis generating and will form the basis of future prospective research.

Highlights

  • The surgical insult of orthotopic liver transplantation (OLT)–coupled with the consequences of end-stage liver disease–increase the potential for major blood loss and fluid shifts, making it a high-risk surgical procedure

  • Except for tricuspid annular plane systolic excursion at five minutes prior to reperfusion, no echocardiographic metric was statistically significantly different at any timepoint relative to baseline

  • Changes in right ventricular outflow tract gradient and right ventricular dP/dt were highly significant at multiple timepoints, generally peaking immediately before or after reperfusion before reducing, but not returning to baseline in the neohepatic phase

Read more

Summary

Introduction

The surgical insult of orthotopic liver transplantation (OLT)–coupled with the consequences of end-stage liver disease–increase the potential for major blood loss and fluid shifts, making it a high-risk surgical procedure. Hemodynamic perturbation during OLT is common, around the time of reperfusion. Such instability is associated with operative morbidity and mortality, and has an incidence of 12–77% depending on the case series reviewed [1, 2]. Despite increasing attention in the cardiac anesthesiology literature, continuous measurement of right ventricular pressure using a pulmonary artery catheter has not been described in orthotopic liver transplantation, despite similarities in the anesthetic approach to the two populations. We describe our preliminary experience with this technique in orthotopic liver transplantation, and by combining various derived measures with trans-esophageal echocardiography, make some early observations regarding the response of these measures of right ventricular function during the procedure

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call