Abstract

The velocities and temperatures of shock waves generated by laser-driven hohlraum radiation fields have been measured for several indirect-drive inertial confinement fusion capsule ablator materials. For the first time, a time-resolved measurement of the preheat temperature ahead of the shock front has been performed and included in the analysis. It is found that preheat ahead of the shock front can cause significant shock propagation variations in the ignition capsule ablator materials being considered for the National Ignition Facility (NIF). If unaccounted for, these preheat effects could potentially preclude ignition at the NIF.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.