Abstract
AbstractDisinfection by chlorine is common practice in potable water treatment. The most frequently used dose control method is to inject an overdose of chlorine at the inlet to the contact tank and adjust to the desired residual chlorine level in the effluent stream. However, this method of control may not be optimal. The advent of reliable predictions of retention time distributions and the widespread use of programmable logic controllers, coupled with a greater understanding of chlorine disinfection kinetics, offers the potential for more efficient chlorine dosing algorithms. This paper describes one possible algorithm, based on theoretical models, for predictive chlorine dosing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.