Abstract

ObjectiveTo examine the role of a key hemodynamic parameter, namely the true and false lumen pressure difference, to predict progressive aortic dilatation following type A aortic dissection (TAAD) repair. MethodsFour patients with surgically repaired TAAD with multiple follow-up computed tomography angiography scans (4-5 scans per patient; N = 18) were included. Through-plane diameter of the residual native thoracic aorta was measured in various aortic segments during the follow up period (mean follow-up: 49.6 ± 31.2 months). Computational flow analysis was performed to estimate true and false lumen pressure difference at the same locations and the correlation with aortic size change was studied using a linear mixed effects model. ResultsGreater pressure difference between the true and false lumen was consistent with greater aortic diameter expansion during the follow up period (linear mixed effects analysis; coefficient, 0.26; 95% confidence interval, 0.15-0.37; P < .001). Based on our limited data points, a pressure difference higher than 5 mm Hg might cause unstable aortic growth. ConclusionsComputational fluid dynamic assessment of standard aortic computed tomography angiography offers a noninvasive technique that predicts the risk of aortic dilatation following TAAD. The technique may be used to plan closer observation or intervention in high-risk patients.