Abstract
To predict round window niche (RWN) visibility using high-resolution computed tomography (HRCT). We retrospectively reviewed the pre-surgical axial HRCT scan of 110 patients who underwent cochlear implantation and compared the CT visibility of RWN with the intraoperative findings by reviewing the operative notes and replaying the surgical video recording. The shape of RWN was determined using the HRCT slice with maximum RWN visibility. Accordingly, it was classified as the O-shaped or C-shaped RWN. Based on the surgical view, RWN visibility was classified as clearly visible or difficult to visualize. Radiological findings were correlated with the surgical view. Seventy-six cases (69%) showed clear RWN visibility; of them, 66 correlated with the HRCT finding C-shaped RWN. Of the other 34 cases (31%) with difficult RWN visualization, 26 correlated with the HRCT finding O-shaped RWN. The sensitivity and specificity of the HRCT finding in predicting the difficulty in visualization of RWN were 79.4% and 86.8%, respectively. The RWN shape on HRCT can be a simple and useful method in predicting RWN visibility through posterior tympanotomy approach in cochlear implantation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.