Abstract
The paper investigates the accuracy of the AASHTO simplified method by using load measurements reported in a large database of full-scale instrumented walls for bar mat, welded wire, and steel strip soil reinforced walls. The accuracy of the AASHTO simplified method is quantified by computing the mean and coefficient of variation of the ratio (bias) of measured loads under operational conditions to predicted loads. The paper shows that for steel strip walls, the AASHTO simplified method is reasonably accurate for granular backfill soils with friction angles less than 45°. For bar mat walls, the method is demonstrated to be slightly conservative. The simplified method underpredicts reinforcement loads at shallow overburden depths for steel strip walls with backfill friction angles greater than 45° due to compaction-related effects. It is concluded that these compaction-induced loads near the wall top do not contribute to internal instability due to pullout.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have