Abstract
A mixed micelle-mediated cloud point extraction procedure was developed for lead. Triton-X114 and benzyldimethyl hexadecyl-ammonium chloride were used as mixed micellar medium. Lead(II) was reacted with 4-(2-pyridylazo) resorcinol at pH 6.0 to form hydrophobic chelates. The parameters including pH, ligand volume, concentrations of surfactants and centrifugation time were optimized. The effect of some common ions was also tested. The limit of detection was 1.15μgL−1 with preconcentration factor of 50. The accuracy of method was evaluated by the analysis of certified reference materials. The method was successfully applied to determination of levels of lead in water samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.