Abstract
Pure titanium (Ti) is investigated in a pre-clinical study in Hank's biological solution using electrochemical methods, open circuit potential, and electrochemical impedance spectroscopy to highlight the time effect in extreme body conditions, such as inflammatory diseases, on degradability due to corrosion processes occurring on the titanium implant. Electrochemical impedance spectroscopy (EIS) data are presented as Nyquist and Bode plots. The results show the increasing reactivity of titanium implants in the presence of hydrogen peroxide, which is an oxygen-reactive compound that describes inflammatory conditions. The polarization resistance, which results from electrochemical impedance spectroscopy measurements, declined dramatically from the highest value registered in Hank's solution to smaller values registered in all solutions when different concentrations of hydrogen peroxide were tested. The EIS analysis provided insights into titanium's in vitro corrosion behavior as an implanted biomaterial, which could not be solely obtained through potentiodynamic polarization testing.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.