Abstract

Nitrogen depth profiling in a high-k gate stack structure, SiON/HfO2/SiON/Si(0 0 1) was performed by high-resolution Rutherford backscattering spectroscopy (HRBS) in combination with angle-resolved X-ray photoelectron spectroscopy (AR-XPS). The nitrogen depth profile is determined so that both the HRBS spectrum and the angular dependence of the XPS yield are reproduced. The obtained nitrogen profile is compared with the result of high-resolution elastic recoil detection (ERD) which is the most reliable technique for depth profiling of light elements. The agreement between the result of the present combination analysis and that of high-resolution ERD is fairly good, showing that the present combination analysis is a promising method for the analysis of light elements.