Abstract

The data on the measured static breakdown voltages and pre-breakdown currents flowing in the main gap of a two-section, sealed-off thyratron with a cold-cathode TPI1-10k/50 are presented. It is shown that pre-breakdown current in the lower section appears at lower voltages than in the upper section. A few methods are proposed for increasing the thyratron breakdown voltage via re-distribution of the voltage between the sections using capacitive and resistive voltage dividers. It is demonstrated that either the self-capacitance of one of the sections or the resistance due to the pre-breakdown current flow could serve as one of the arms of the divider.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.