Abstract

The data on prebreakdown currents and static breakdown voltages measured in two-sectioned sealed-off thyratron with a cold cathode TPI1-10k/50 are presented. The temporal behavior of the anode voltage and of the voltage at the separate sections has been investigated at the prebreakdown and breakdown stages. It is demonstrated that the prebreakdown current presented in the separate sections causes redistribution of the anode voltage between the sections. Due to this effect, a maximum thyratron breakdown voltage can be obtained. The other method to increase the breakdown voltage is based on the forced distribution of the anode voltage between the sections using a capacitive divider. Special features of transition from the prebreakdown to breakdown current are discussed for different thyratron-switching circuits.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.