Abstract

AbstractAspen Plus® simulations using the Peng‐Robinson (PR‐EOS) and the COSMO‐SAC models were performed to study absorption power cycles (APCs) using mixtures of R‐134a with two ionic liquids, [C2C1im][Tf2N] or [C6C1im][Tf2N], and compared against an R‐134a organic Rankine cycle (ORC) operating under similar conditions. The PR‐EOS results were in agreement with calculations from a PR model fitted to the R‐134a + IL experimental phase equilibrium data. The APCs have similar efficiencies and outperform the ORC by 3%–46%, with the largest differences observed when operating with lower grade (lower TH) heating sources, lower quality cooling (higher TL), and lower subcooling in the pump inlet stream. The PR‐EOS and the Conductor‐like Screening Model Segment Activity Coefficient (COSMO‐SAC) results follow similar trends, but numerical discrepancies are observed in the cycle efficiencies and stream flow rates and compositions due to differences in solubilities and enthalpy changes between both models, suggesting that improvements are needed to increase the accuracy of COSMO‐SAC for these systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.