Abstract

The feasibility of using inlet air cooling by virtue of the cold energy of liquefied natural gas (LNG) to increase power output of gas/steam combined cycle power plants during warm seasons is analyzed. Air cooling capacity and power augmentation for a combined cycle system based on a high performance gas turbine are demonstrated as a function of the ambient temperature and humidity. It is shown that the relative increase in power of the combined cycle plant amounts to 8% for dry air condition (relative humidity lower than 30%) and 6% for usual humidity conditions (60% relative humidity). The system appears feasible even with a realistic air pressure loss in the inlet air cooler if humidity is not too high.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.