Abstract
The potential of near-infrared reflectance spectroscopy (NIRS) to predict soil organic C in different particle-size fractions was evaluated. Soil samples ( n = 180) from various crop rotations in Uruguay were analysed by standard chemical and NIRS methods. Partial least squares (PLS) regression with cross validation was used to develop calibrations between reference data and NIRS spectra ( n = 87) and validated using an independent set of samples ( n = 87). Coefficients of determination in calibration ( R CAL 2 ) and standard errors in cross validation (SECV) were 0.90 and 0.6 for coarse-sand C, 0.92 and 0.4 for fine-sand C, and 0.96 and 2.1 for clay + silt C, respectively. Calibrations were poor for C/N ratio ( R CAL 2 < 0.65). Although NIRS demonstrated great potential to predict soil organic C in different particle-size fractions, the nature of sampling and number of samples analysed should be considered in future developments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.