Abstract
Acid-induced milk coagulation is a key processing step in the manufacture of dairy products i.e. yoghurt, and could benefit from process analytical technologies for monitoring the kinetics of milk coagulation. This study evaluates a novel, bulk acoustic wave (BAW) sensor technology to monitor acid-induced (glucono-delta-lactone (GDL)) coagulation of skim milk. The effects of GDL concentration (2.5, 3 and 3.5%) and temperature (22, 31 and 40 °C) on skim milk coagulation kinetics were evaluated using rheometry and the BAW sensor. A parameter tAVg, determined from acoustic viscosity (AV), was established to monitor the onset of gelation. Changes observed in tAVg at the onset of gelation were due to changes in particle size of samples at pH ∼5.3 and ∼5.2. A positive linear relationship (R2 = 0.97) were found between gelation point (G′ > 1 Pa) and tAVg, and was capable to monitor early stages of gel formation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.