Abstract

One of the major components in a fusion reactor for which a safety analysis must be carried out is the magnet system. We attempt to provide a systematic answer to the hazard potential of superconducting magnets for fusion. Event trees are developed, demonstrating the predictable behavior in all cases. It can be seen that usual failure events cause only a temporary shutdown of the magnet system without damage. Less likely accidental events will lead to single-current arcs with moderate internal damage of a single coil. Only sudden complete rupture of a turn can be followed by a multiple-current arcing resulting in a very high power arc with a certain probability of burning through the coil case, thus damaging other reactor components before extinction. Missile generation of winding parts can only occur in the very hypothetical case of simultaneous rupture of the winding at a sufficiently large distance apart. Even then, the developed kinetic energy will be less than that of airplane crashes considered in the safety analysis of nuclear power plants.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.