Abstract

BackgroundAs part of clinical wound assessment in bovine surgery, discrepancies in skin temperature are evaluated by placing the back of the hand on the area to be examined. Generally, an increased skin temperature at the wound site for a prolonged period is considered as an indicator of impaired wound healing.The aim of this study was to verify the reliability of palpation under bovine practice conditions using laparotomy as an example. Fourteen cows (German Holstein) with a left displacement of the abomasum (LDA) without other severe concurrent diseases were examined preoperatively and once daily for ten days after surgery. The skin temperature of the wound site in the right flank was assessed by palpation, followed by thermographic evaluation using an infrared camera after a 45-min acclimatisation period, under standardised conditions in a closed examination room daily for 10 days.ResultsAll the incisions healed without clinical detectable perturbances. The ambient temperature range during the study period was 7.8 − 24.1 °C. Two groups were retrospectively defined according to the ambient temperature: high ambient temperature (HT group; median: 20.2 °C 25/75 quartile: 18.5 °C / 21.7 °C; n = 6) and low ambient temperature (LT group; 10.8 °C; 9.4 °C / 12.8 °C; n = 8). The temperature differences (Δϑ) between the mean skin temperature of the wound site and a defined reference area cranial to the wound were assessed. A significant negative correlation was found between the ambient temperature (ϑAmb) and Δϑ (r=-0.51; P < 0.001). The Δϑ was postoperatively higher in the cows in the LT group (median of the individual animals 0.8–2.5 °C) than in the HT group (0.1–0.5 °C; P < 0.05). In contrast to the thermographic findings, manual palpation rarely detected local hyperthermia (> 1 °C) at the wound site (sensitivity 0.20; specificity 0.96).ConclusionsThe infrared thermography provides a more reliable assessment of temperature changes at the wound site in comparison to manual palpation. The ambient temperature markedly affects the extent of local hyperthermia at the wound site.

Highlights

  • As part of clinical wound assessment in bovine surgery, discrepancies in skin temperature are evaluated by placing the back of the hand on the area to be examined

  • Disturbed postoperative wound healing can delay the recovery of cows and increase treatment costs

  • The aim of the present study was to investigate the reliability of palpation in estimating skin temperature under working conditions

Read more

Summary

Introduction

As part of clinical wound assessment in bovine surgery, discrepancies in skin temperature are evaluated by placing the back of the hand on the area to be examined. An increased skin temperature at the wound site for a prolonged period is considered as an indicator of impaired wound healing. The skin temperature of the wound site in the right flank was assessed by palpation, followed by thermographic evaluation using an infrared camera after a 45-min acclimatisation period, under standardised conditions in a closed examination room daily for 10 days. We compared the results of the palpation assessment of the skin temperature with the IR thermography measurements during the postoperative period of cows undergoing right flank laparotomy and omentopexy

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call