Abstract

Purpose To evaluate the relationship between posterior capsule folds and an ophthalmic viscosurgical device (OVD) during cataract surgery. Setting Parkland Memorial Hospital, Dallas, Texas, USA. Methods A prospective observational study of 91 consecutive uneventful cataract extractions by phacoemulsification was performed. The presence or absence of posterior capsule folds was noted immediately after intraocular lens (IOL) implantation and after OVD removal. Results Posterior capsule folds were present in 21 of 49 cases (43%) with an MA60BM lens (Alcon Laboratories) and in 1 of 42 cases (2%) with an SA30AL lens. In the MA60BM group with folds, the folds were noted before OVD removal in 14 cases and after OVD removal in 16 cases. There was no significant difference in age, sex, axial length, horizontal corneal diameter, or IOL power between groups with and without posterior capsule folds. Conclusion The presence of posterior capsule folds does not reliably signify the complete removal of OVDs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call