An experiment was performed at the National Ignition Facility investigating the ablative Rayleigh-Taylor instability’s dependence on initial conditions in the highly nonlinear stage. The detailed post-processing of the radiographic images which includes backlighter reconstruction, Wiener deconvolution of the raw data, and the calculation of a conversion factor from optical depth to physical units. The results of these calculations were fed into the primary analysis of the experimental data, with this manuscript serving as a supplemental reference to the primary paper [1].

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.