Abstract

We tested the use of nasal swabs spotted onto filter paper (Whatman 3M) for the molecular diagnosis of SARS‐CoV‐2 infection. Spots of a positive nasal swab in conservation medium (B.1.177 strain, 21Ct) were still positive (duo E‐gene/IP4) after 10, 20, and 30 days of conservation at room temperature, with Ct values of 28, 27, and 26, respectively. Direct spotting of the swab at bedside (omicron strain) still gave a positive result after 10 days in two RT‐qPCR systems: 33.7 Ct using duo E‐gene/IP4, and 34.8 using a specific Omicron system. Spotting of a dilution range of media spiked with the Delta (strain 2021/FR/0610, lineage B 1.617.2) and Omicron strains (strain UVE/SARS‐CoV‐2/2021/FR/1514) showed a threshold of 0.04 TCID50 after 10 days of conservation. We show, for the first time, that this simple and low‐cost conservation method can be used to store samples for RT‐qPCR against SARS‐CoV‐2 for up to at least 1 month.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.