Abstract

Syringomyelia, fluid-filled cavities within the spinal cord, occurs frequently in association with a Chiari I malformation and produces some of its most severe neurological symptoms. The exact mechanism causing syringomyelia remains unknown. Since syringomyelia occurs frequently in association with obstructed cerebrospinal fluid (CSF) flow, it has been hypothesized that syrinx formation is mechanically driven. In this study we model the spinal cord tissue either as a poro-elastic medium or as a solid linear elastic medium, and simulate the propagation of pressure waves through an anatomically plausible 3D geometry, with boundary conditions based on in vivo CSF pressure measurements. Then various anatomic and tissue properties are modified, resulting in a total of 11 variations of the model that are compared. The results show that an open segment of the central canal and a stiff pia (relative to the cord) both increase the radial pressure gradients and enhance interstitial fluid flow in the central canal. The anterior median fissure, anisotropic permeability of the white matter, and Poisson ratio play minor roles.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.