Abstract

Pool boiling heat transfer of R11 is investigated experimentally and theoretically on single tubes and twin tube arrangements. Finned tubes with 19 and 26 fins per inch (fpi) are used. The refrigerant evaporates at a saturation state of 1 bar on the outside of the electrically heated tubes. For the twin tube arrangements the tube pitch is varied between, s/dF = 3.0 and 1.05. The heat transfer on the upper tube of the twin tubes is enhanced compared with the single tube, while the heat transfer on the lower tube is not affected by the upper tube. The maximum heat transfer of the upper tube increases with increasing tube pitch.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.